Requirement | CESQG (Chap 8) | SQG (Chap 9) | LQG (Chap 10) |
Identify Hazardous Waste (Chap 4) | Yes | Yes | Yes |
Generation Limits | < 100 kg/mo
(< 220 lb/mo) | Between 100 and 1,000 kg/mo
(Between 220 and 2,200 lb/mo.) | > 1,000 kg/mo
(> 2,200 lb/mo) |
Acute Hazardous Waste Limits | < 1 kg/mo
(< 2.20 lb/mo) | < 1 kg/mo
(< 2.20 lb/mo) | > 1kg/mo
(> 2.2lb/mo) |
Facility Receiving Waste | State approved or RCRA permitted | RCRA-permitted facility | RCRA-permitted facility |
USEPA ID Number (Chap 4) | Not required | Required | Required |
RCRA Personnel Training | Not required | Familiarization required | Required |
DOT Training (49 CFR) | Required | Required | Required |
Exception Report | Not required | Required > 60 days | Required > 45 days |
Biennial Report | Not required | Not required | Required (Chap 4) |
On-site accumulation limits (without permit) | < 1,000 kg
(< 2,200 lb) | < 6,000 kg
(< 13,200 lb) | Any quantity |
Accumulation Time Limits (without permit) | None | < 180 days or
< 270 days if ≥ 200 miles to disposal facility (Chap 9) | < 90 days + an additional 30 days if granted extension by NDEE (Chap 10) |
Storage Requirements | None | Basic standards for containers or tanks (Chap 9) | Full compliance with management of containers or tanks (Chap 10) |
Arrangements With Local Authorities | None | Required (Chap 17) | Required (Chap 17) |
Emergency Equipment & Communications | None | Required (Chap 17) | Required (Chap 17) |
Contingency Plan | None | None | Required (Chap 18) |
Emergency Coordinator | None | Required | Required |
Telephone Information | None | Post information by phone | In Contingency Plan |
Use Manifests | No | Yes, unless waste is reclaimed under contractual agreement | Yes |